HP (Hewlett-Packard) HP PART NUMBER: 461487-401A All in One Printer User Manual


 
After the issue is resolved, any disk can be added (which might involve upgrading the virtual
hardware on the virtual machine.)
Server is unresponsive during PSP installation
The server becomes unresponsive during PSP installation.
Suggested action
Reboot the server and then reinstall PSP manually.
Destination server still shows server migration UI but server migration wizard shows
migration completed
After the migration, server migration loses connectivity to the Hyper-V host, which causes server
migration to fail to eject the boot CD and reboot the VM. If server migration cannot connect to the
Hyper-V host, reboot by using the destination agent. In this case, server migration will be unable
to eject the boot CD and as a result, after the reboot, the VM will boot back into the boot CD. This
issue is specific to Microsoft Hyper-V VMs.
Suggested action
Manually eject the virtual boot CD from the VM and reboot the VM.
Operating system is not booting on a destination server that has SAN disks
After you perform a successful P2P migration of the SLES 11 SP1 32-bit operating system on SAN
disks with Brocade or QLogic Fibre Channel HBA as the primary boot controller, the operating
system does not boot on the destination server.
Suggested action
Before you migrate any Linux distribution to a destination server that has SAN storage, make sure
that the RPM package containing firmware files (such as
brocade-firmware-<version>.noarch.rpm and
qlogic-firmware-<version>.noarch.rpm on SLES OS, and
ql2xxx-firmware-<version>.noarch.rpm on RHEL OS) for the target SAN Fibre Channel
HBA are installed on the source server from the OS installation media.
Error is displayed for a missing file system while migrated Linux OS is booted on the
destination server
When you migrate a file system to the destination server multiple times, the multiple file systems
that contain the same UUID are created.
Suggested action
Make sure that multipath is configured on the source server. If multipath is not configured, make
sure that the file systems that are being migrated do not have the same UUID.
Logical drives of HP Smart Array B110i SATA RAID Controller are removed
After a successful X2P migration of the Windows Server 2008 OS, the logical drives of HP Smart
Array B110i SATA RAID Controller are removed.
Suggested action
When the logical drives are removed, you must re-create the exact logical drives by using ACU
or ORCA on the destination server after migration.
70 Troubleshooting