IBM
Enhanced
Diagnostic
error
codes
Refer
to
the
following
diagnostic
error
codes
when
using
the
diagnostic
tests.
See
“Diagnostics
and
test
information”
on
page
5
for
the
specific
type
for
information
about
the
diagnostic
programs.
In
the
following
index,
X
can
represent
any
number.
Diagnostic
Error
Code
FRU/Action
000-000-XXX
BIOS
Test
Passed
1.
No
action
000-002-XXX
BIOS
Timeout
1.
Flash
the
system
2.
System
board
000-024-XXX
BIOS
Addressing
test
failure
1.
Flash
the
system
2.
System
board
000-025-XXX
BIOS
Checksum
Value
error
1.
Flash
the
system
2.
Boot
block
3.
System
board
000-026-XXX
FLASH
data
error
1.
Flash
the
system
2.
Boot
block
3.
System
board
000-027-XXX
BIOS
Configuration/Setup
error
1.
Run
Setup
2.
Flash
the
system
3.
Boot
block
4.
System
board
000-034-XXX
BIOS
Buffer
Allocation
failure
1.
Reboot
the
system
2.
Flash
the
system
3.
Run
memory
test
4.
System
board
000-035-XXX
BIOS
Reset
Condition
detected
1.
Flash
the
system
2.
System
board
000-036-XXX
BIOS
Register
error
1.
Flash
the
system
2.
Boot
block
3.
System
board
000-038-XXX
BIOS
Extension
failure
1.
Flash
the
system
2.
Adapter
card
3.
System
board
000-039-XXX
BIOS
DMI
data
error
1.
Flash
the
system
2.
System
board
000-195-XXX
BIOS
Test
aborted
by
user
1.
Information
2.
Re-start
the
test,
if
necessary
000-196-XXX
BIOS
test
halt,
error
threshold
exceeded
1.
Press
F3
to
review
the
log
file
2.
Re-start
the
test
to
reset
the
log
file
Chapter
5.
Symptom-to-FRU
Index
37