Diagnostic
Error
Code
FRU/Action
030-00X-XXX
030-01X-XXX
SCSI
interface
failure
1.
SCSI
signal
cable
2.
Check
power
supply
3.
SCSI
device
4.
SCSI
adapter
card,
if
installed
5.
System
board
030-027-XXX
SCSI
interface
Configuration/Setup
error
1.
SCSI
signal
cable
2.
Flash
the
system
3.
SCSI
device
4.
SCSI
adapter
card,
if
installed
5.
System
board
030-03X-XXX
030-04X-XXX
SCSI
interface
error
1.
SCSI
signal
cable
2.
Check
power
supply
3.
SCSI
device
4.
SCSI
adapter
card,
if
installed
5.
installed
System
board
030-195-XXX
SCSI
interface
Test
aborted
by
user
1.
Information
2.
Re-start
the
test,
if
necessary
030-196-XXX
SCSI
interface
test
halt,
error
threshold
exceeded
1.
Press
F3
to
review
the
log
file
2.
Re-start
the
test
to
reset
the
log
file
030-197-XXX
SCSI
interface
test
warning
1.
Make
sure
the
component
that
is
called
out
is
connected
and/or
enabled
2.
Re-run
test
3.
Component
that
is
called
out
in
warning
statement
4.
Component
under
test
030-198-XXX
SCSI
interface
test
aborted
1.
If
a
component
is
called
out,
make
sure
it
is
connected
and/or
enabled
2.
Flash
the
system
and
re-test
3.
Go
to
the
″Undetermined
problems″
section
030-199-XXX
SCSI
interface
test
failed,
cause
unknown
1.
Go
to
the
″Undetermined
problems″
section
2.
Flash
the
system
and
re-test
3.
Replace
component
under
function
test
035-000-XXX
RAID
interface
Test
Passed
1.
No
action
035-0XX-XXX
RAID
interface
Failure
1.
RAID
signal
cable
2.
RAID
device
3.
RAID
adapter
card,
if
installed
4.
System
board
035-195-XXX
RAID
interface
Test
aborted
by
user
1.
Information
2.
Re-start
the
test,
if
necessary
48
Hardware