Diagnostic
Error
Code
FRU/Action
175-199-XXX
Thermal
Sensor(s)
test
failed,
cause
unknown
1.
Go
to
the
″Undetermined
problems″
section
2.
Flash
the
system
and
re-test
3.
Replace
component
under
function
test
175-250-XXX
175-251-XXX
Thermal
Sensor(s)
limit
error
1.
Check
fans
2.
Check
Power
supply
3.
Microprocessor
4.
System
board
185-000-XXX
Asset
Security
Test
Passed
1.
No
action
185-XXX-XXX
Asset
Security
failure
1.
Flash
system
2.
System
board
185-278-XXX
Asset
Security
Chassis
Intrusion
1.
Assure
Asset
Security
Enabled
2.
C2
Cover
Switch
3.
System
board
201-000-XXX
System
Memory
Test
Passed
1.
No
action
201-XXX-XXX
System
Memory
error
1.
Replace
the
memory
module
called
out
by
the
test
2.
System
board
202-000-XXX
System
Cache
Test
Passed
1.
No
action
202-XXX-XXX
System
Cache
error
1.
Cache,
if
removable
2.
System
board
3.
Microprocessor
206-000-XXX
Diskette
Drive
Test
Passed
1.
No
action
206-XXX-XXX
Diskette
Drive
error
1.
Diskette
Drive
Cable
2.
Check
power
supply
voltages
3.
Diskette
drive
4.
System
board
215-000-XXX
CD-ROM
Drive
Test
Passed
1.
No
action
215-XXX-XXX
CD-ROM
Drive
error
1.
CD-ROM
Drive
Cable
2.
Check
power
supply
voltages
3.
CD-ROM
drive
4.
System
board
217-000-XXX
Hard
Disk
Drive
Test
Passed
1.
No
action
217-25X-XXX
217-26X-XXX
Hard
Disk
Drive
(IDE)
error
1.
Hard
Disk
Drive
Cable
2.
Check
power
supply
voltages
3.
Hard
Disk
drive
(IDE)
4.
System
board
Chapter
5.
Symptom-to-FRU
Index
53