v If the Align Column Right command is received but the line is filled
before an EOL is received, the filled line is treated as an EOL. There are
usually a few dot positions available, but not enough for a full character.
The column alignment will occur on the few dot positions available.
Set error recovery function
Syntax:
ESCc4n or X'1B63;34;n'
Where:
n Selects the function.
Bit # ↓ Function Bit=0 Bit=1
LSB 0 Reserved N/A N/A
1 Reserved N/A N/A
2 Release Print Buffer after Error
Correction
Release Hold
32 Automatic retry on a Home Error Enabled Not Enabled
4 Hold buffer when waiting for a
document
Release Hold
5 Hold buffer after a flip error Release Hold
Default:
n=00
Remarks:
When set to not automatically release the print buffer after error correction
(bit #2), the printer does not execute commands until it receives a
“Real-time requests” on page 74 command to cancel or release the print
buffer.
When automatic retry on a home error is selected, the printer will try to
reset the print head to a known location, then reprint the line on which the
error occurred. If the printer is unable to reset the print head, operator
intervention is needed.
An error will be sent back to the system and the LED will blink.
Define document wait time
Syntax:
ESC f xyor X'1B66;x;y'
Where:
x Time the printer should wait, from receiving a print line for the
document station until the document is inserted.
If the document has not been detected by the time the wait time
ends, a document error is sent to the system. The system continues
to wait for a document to be inserted.
WaitTime=x*0.5seconds
y Delay from the time the document is detected until it is grabbed by
the printer (start of document printing):
v Side insertion - closes the document throat.
v Front insertion - pulls the document into the printer and feeds it
to its top of form.
Chapter 2. Communication parameters 49