Service processor error codes
When viewed in the system-error log, the Remote Supervisor Adapter II messages
will appear as text descriptions. To determine a possible error condition for the
Remote Supervisor Adapter II, see the system-error log (see “Starting the diagnostic
programs and viewing the test log” on page 17).
SCSI error codes
Error code FRU/action
All SCSI Errors One or more of the following
might be causing the problem:
v A failing SCSI device
(adapter, drive, controller)
v An improper SCSI configuration or SCSI
termination jumper setting
v Duplicate SCSI IDs in the same SCSI chain
v A missing or improperly installed SCSI
terminator
v A defective SCSI terminator
v An improperly installed cable
v A defective cable
1. External SCSI devices must be turned on before you
turn on the computer.
2. Make sure that the cables for all external SCSI devices are
connected correctly.
3. If you have attached an external SCSI device to the
computer, make sure the external SCSI termination is set to
automatic.
4. Make sure that the last device in each SCSI chain is
terminated correctly.
5. Make sure that the SCSI devices are configured correctly.
104 IntelliStation Z Pro Types 6223 and 6227: Hardware Maintenance Manual and Troubleshooting Guide