IBM Type 8720 Server User Manual


 
v Reinstall the LAN module (see “Installing the LAN module” on page 59).
v Reinstall the KVM module (see “Installing the KVM module” on page 57).
v Reinstall the I/O switches or switch fillers.
v Reinstall the two blowers (see “Installing a blower module” on page 55).
v For Type 8720 (dc) units, connect the power cables to the dc terminals and
dc terminal covers. For Type 8730 (ac) units, plug each power cord into the
input power connections on the rear of the BladeCenter T unit.
v Reinstall the power modules at the front of the unit (see “Installing a power
module” on page 48).
7.
Start up the system (see “Starting the BladeCenter T unit” on page 19).
Air damper
Complete the following steps to replace an air damper.
Note:
v Read “Installation guidelines” on page 37.
v Read the safety notices at Safety information on page 113.
v Read “Handling static-sensitive devices” on page 40.
1. Shut down the system and remove power from the system (see “Shutting
down the BladeCenter T unit” on page 21).
2. Remove the power modules and fillers from the bays at the front of the unit
(see “Removing and installing power modules” on page 46).
3. Remove the management modules and fillers from the bays at the front of the
unit (see “Removing a management module” on page 52).
4. Remove the media tray at the front of the unit (see “Removing the media tray”
on page 50).
5. Remove the server blades and fillers from the front of the unit (see “Removing
a blade server” on page 66).
6. Remove the broken air damper from the server.
82 BladeCenter T Type 8720 and 8730: Hardware Maintenance Manual and Troubleshooting Guide