40
CHAPTER 3
Intel Express 10/100 Fast Ethernet Switch
The screen displays the following information:
• SNMP agent software version and release date.
• Device SNMP object ID.
• Device MAC address.
• System uptime (in 1/100 of a second) and in days, hours, minutes,
and seconds.
• Port description and status. Ports 9 through 12 are labeled as
“missing” unless you have optional media adapters installed.
get-stst-level
Displays the self-test level set by the
set-stst-level command.
set-stst-level
set-stst-level {none|short|long}
Changes the self-test level. The switch performs a self-test each time
you reset it with the
cold-reset command or when you cycle the
power. The default is
none.
warm-reset
Resets the SNMP agent software without resetting the switch (it
doesn’t disconnect existing connections). The switch configuration is
loaded from the values saved in NVRAM. This command also resets
the statistics counters.
cold-reset
Performs a cold reset, which is the same as turning the power off then
on again. Any existing connections are lost and the statistics counters
are reset.
get-last-err
Displays the most recent system failure, if any, for diagnostic
purposes.
SYS_console>get-last-err
System information since the last hardware reset
————————————————————————
Software resets number : 0
The system never encountered a fatal error