4.1.2.4 Hardware Health Configuration
4.1.2.4.1 H/W Health Function
Enables Hardware Health Monitoring Device.
4.1.2.4.2 FAN 1 Mode Setting
This item allows you to set fan speed control mode.
Option: [Full On mode], [Automatic mode].
4.1.2.4.3 Temperature 1 Limit of Start
Fan spins in a start PWM value when temp exceeds a start limit
Min=0℃, Max=127℃, Please input Dec number:
4.1.2.4.4 Fan 1 Start PWM
Fan start PWM value.
Min=0, Max=127, Please input Dec number.
4.1.2.4.5 Slope PWM 1
The PWM value is subject to the temperature inputs by linear changing.
4.1.2.4.6 FAN 2 Mode Setting
This item allows you to set fan speed control mode.
Option: [Full On mode], [Automatic mode].
4.1.2.4.7 Temperature 2 Limit of Start
Fan spins in a start PWM value when temp exceeds a start limit
Min=0℃, Max=127℃, Please input Dec number: