Intel PRO/100 Network Router User Manual


 
6-28 PRO/100 LAN+Modem PC Card User’s Guide
S8 Duration of Pause for Comma Dial Modi-
fier
This register determines the number of seconds to pause for each
comma (,) in a dial string or command line. The default is 2
seconds, but any value from zero to 65 is acceptable. Defaults and
limits are country-specific.
S10 Delay Between Lost Carrier/Hang Up
This register specifies the time (in tenths of a second) that the
modem waits after carrier loss before hanging up. The default is 20
(2.0 seconds). This allows for temporary carrier loss without causing
the local modem to disconnect. Register S10 will accept a value
ranging from 1 to 254 in tenths of a second (0.1 to 25.4 seconds).
Defaults and limits are country-specific.
S11 DTMF Tone Duration
This register determines the touch tone dialing speed which is
prefixed for each country. The value can range from 50 to 150
milliseconds. The default is 95 milliseconds. The value of register
S11 has no effect on pulse dialing. Defaults and limits are country-
specific.
S12 Escape Guard Time
This register sets the value (in 20 ms increments) of the required
pause after the escape sequence. Range is 0 = 255, default is 50 units
of 0.02 seconds each, or one second.
S28 V.34 Modulation Enable/Disable
This register enables or disables V.34 modulation. Default setting is
1, valid values are 0 or 1. A value of zero disables V.34 modulation.
Any other value in the range enables it.
S30 Inactivity Timer
The value specified by this register sets how long the modem will
wait (in minutes) before disconnecting when no data is sent or
received. This function is only applicable in buffer mode. It is set