Intel PRO/100 Network Router User Manual


 
4-50 PRO/100 LAN+Modem PC Card User’s Guide
The I/O test failed - Please select a different I/O address
The driver failed the I/O test. Try a different I/O address.
The IRQ test failed - Please select a different IRQ
The driver failed the IRQ test. Try a different IRQ address.
Please specify either IO or MEM for the MODE keyword
This message applies to both the ODI and NDIS 2.0 drivers. The value
specified under the MODE keyword in the NET.CFG or
PROTOCOL.INI file must be either IO or MEM.
Please specify a decimal number for the COMIRQ keyword
This message applies to both the ODI and NDIS 2.0 drivers. The value
specified under the COMIRQ keyword in the NET.CFG or
PROTOCOL.INI file must be a decimal number.
Please specify a hexadecimal number ending in 8 for the
COMBASE keyword
This message applies to both the ODI and NDIS 2.0 drivers. The value
specified under the COMBASE keyword in the NET.CFG or
PROTOCOL.INI file must be a hexadecimal number in the range 248 to
3F8.
No standard COM ports available. Please use custom COM port
(COMIRQ, COMBASE)
This message applies to both the ODI and NDIS 2.0 drivers. All COM
ports (COM1 - COM4) are being used. Create a custom COM port by
adding the COMIRQ and COMBASE keywords, with assigned values, to
the NET.CFG or PROTOCOL.INI file.
The selected COM IRQ is in use by another device
The IRQ value set for the COM port is already in use by another device.
Assign a different IRQ value for the COM port.