Intel PRO/100 Network Router User Manual


 
Windows NT Installation 3-9
Parameter Default Valid Values Registry Value
DIRECT ENABLE DISABLED DISABLED 0
ENABLED 1
EARLY TRANSMIT ENABLED DISABLED 0
ENABLED 1
FULL DUPLEX DISABLED DISABLED 0
ENABLED 1
FUNCTION(S) NETWORK NETWORK & MODEM 0
NETWORK ONLY 1
MODEM ONLY 2
INTERRUPT 5 3, 4, 5, 7, SAME
10, 11, 15
I/O PORT 0X320 0X200-0X3D0 SAME
I/O PORT 0X2E8 3F8,2F8,3E8,2E8 SAME
LINE SPEED AUTO DETECT AUTO DETECT 0
10MBPS 1
100MBPS 2
LINK INTEGRITY ENABLED DISABLED 0
ENABLED 1
MEMORY ADDRESS 0XD4000 0XA0000 - 0XFE000 SAME
MODE I/O I/O 0
MEMORY MAPPED 1
The network node address can be modified by manually editing the
registry and adding the parameter NetworkAddress with a hexadecimal
string value, such as 00A0C7112233. If the user does NOT specify a
NetworkAddress then the M16B.SYS driver uses the network node
address contained in the PRO/100 PC Card information structure.
There are parameters in the Windows NT registry which specify the
configuration of the PRO/100 PC Card hardware to the M16B.SYS
driver. Many of these parameters correspond directly to the user-
configurable parameters. These parameters are found in the registry at the
following location:
HKEY_LOCAL_MACHINE\SYSTEM\CURRENTCONTROLSET\SERVICES\M16B1\PARAMETERS\