Intel MFS2600KIB Computer Hardware User Manual


 
Functional Architecture Intel
®
Compute Module MFS2600KI TPS
Revision 1.0
Intel order number: G51989-002
26
Intel
®
I350 NIC will be used in conjunction with the Emulex* Pilot-III Management Controller for
out of band Management traffic. The BMC will communicate with Intel
®
I350 NIC over a NC-SI
interface (RMII physical). Intel
®
I350 NIC will be on standby power so that the BMC can send
management traffic over the NC-SI interface to the network during sleep state S5.
3.8 Intel
®
Virtualization Technology for Directed I/O (Intel
®
VT-d)
The Intel
®
C602-J chipset provides hardware support for implementation of Intel
®
Virtualization
Technology with Directed I/O (Intel
®
VT-d). Intel
®
VT-d consists of technology components that
support the virtualization of platforms based on Intel
®
Architecture Processors. Intel
®
VT-d
Technology enables multiple operating systems and applications to run in independent
partitions. A partition behaves like a virtual machine (VM) and provides isolation and protection
across partitions. Each partition is allocated its own subset of host physical memory.