Intel R1304GL4DS9 Server User Manual


 
Server System Features
8 Intel
®
Server System R1000GZ/GL Service Guide
System Recovery Jumpers
Jumper Name Jumper Purpose
A Serial A Jumper (J3A2)
If pins 2-3 are selected, the serial-A configuration is in Data Carrier
Detect (DCD) mode. These pins should be selected on 1-2 for
normal system operation.
B BIOS Recover (J6C4)
If pins 2-3 are selected, the system can only boot from EFI-bootable
recovery media with the recovery BIOS image. The main system
BIOS will not boot. These pins should be selected on 1-2 for normal
system operation.
C ME Force Update (J6C5)
If pins 2-3 are selected, the ME Force Update Mode is enabled.
These pins should be selected on 1-2 for normal system operation.
D Password Clear (J6C6)
If pins 2-3 are selected, administrator and user passwords are cleared
within five to ten seconds after the system is powered on. These pins
should be selected on 1-2 for normal system operation.
E BIOS Default (J6D1)
If pins 2-3 are selected, the BIOS settings are cleared on the next
reset. These pins should be selected on 1-2 for normal system
operation.
F
BMC Force Update (J2D1)
If pins 2-3 are selected, the Integrated BMC Force Update Mode is
enabled. These pins should be selected on 1-2 for normal system
operation.
Figure 9. Configuration Jumpers