Intel R1304GL4DS9 Server User Manual


 
Appendix A: Technical Reference
Intel
®®
Server System R1000GZ/GL Service Guide 47
Appendix A: Technical Reference
Power Supply Input Voltages
460W power supply module
100 - 127 V at 50/60 Hz 5.8 A
200 - 240 V at 50/60 Hz 2.9 A
750W power supply module
100 - 127 V at 50/60 Hz 8.2 A
200 - 240 V at 50/60 Hz 4.4 A
Power Supply Output Voltages
The following table lists the total wattage available from the power subsystem for each voltage. For
information about calculating the power usage for your configuration, please use the Power Budget
Tool.
Table 5. Power Supply Output Capability
Voltage Maximum Current
12V 62.0A
12VSB 2.1A
System Environmental Specifications
The following table defines the system level operating and non-operating environmental limits.
Table 6. System Environmental Limits Summary
Parameter Limits
Operating Temperature +10°C to +35°C with the maximum rate of change not to exceed 10°C per hour
Non-Operating Temperature -40°C to +70°C
Non-Operating Humidity 90%, non-condensing at 35°C
Acoustic noise Sound power: 7.0 BA in operating conditions at typical office ambient temperature.
(23 +/- 2 degrees C)
Shock, operating Half sine, 2 g peak, 11 milliseconds