A-61510 January 2005 4-28
Counter
• Initial Value: this value is used to assign the document count for
the next document entering the transport. This value is incremented
sequentially by the scanner unless another document count is
received from the host. This value is returned in the image header.
• Field Width: used to control the width of the document counter.
Values range from 1 to 9.
• Format the format in which the image address appears when
printed is defined on the Image Address dialog box. The printed
image address may appear in one of three formats:
– Display leading zeros format (e.g., 004.003.002.001)
– Suppress leading zeros format (e.g., 004. 3. 2. 1)
– Compress leading zeros format (e.g., 004.3.2.1)
NOTE: The format chosen does not effect the fixed field of the image
address; it is always displayed and printed in its entirety. In the
example above, 004 has been defined as a fixed field.