Format string this text field allows you to structure your image
address. Fixed field information entered in this field will be reflected in
the Image Address area in Fields A through D. To indicate the position of
an image address level use the format character (%3L – Level 3, %2L –
Level 2, %1L – Level 1) which represents that level. For image address
levels the value indicated in Fields A through D will be the start value as
defined in the Counters area Start Value field. In the dialog box on the
previous page the format string Address%3L%2L%1L represents a fixed
field value of address and a 3 level image address.
The i800 Series Scanners have more options available for image
addressing schemes with the following guidelines:
You may define from 0 to 4 fixed fields. Fixed fields can be a maximum
of 9 characters.
Only one field may be assigned to a level. You are only allowed one level
1 field, one level 2 field, and one level 3 field.
There is no requirement to have any level field.
Image Address fields
Displays the starting image address. The values in this field reflect
information from the Format String area and the Counters area Start
Value field. Each field can have a maximum width of 9 characters. The
total image address cannot exceed 27 characters (30 with 3 delimiters).
Presets you can use the selections in the field to automatically fill in
the format string field. The options are:
Custom – enter you desired values.
Level 3 – Address%3L%2L%1L
Level 2 - Address%2L%1L
Level 1 - Address%1L
Level 3 Offset - Address%3L%2L
Level 2 Offset - Address%2L
You can have no fixed field or enter any fixed field value. The default
fixed field value is Address.