Konica Minolta C650 All in One Printer User Manual


 
C650 3-57
Administrator mode
3
IKE Setting
SA Setting
Item Description
Key Validity Period Specify the validity period of a key generated when creating a control tunnel.
Diffie-Hellman Group Select "Diffie-Hellman Group".
Encryption Algorithm Select the encryption algorithm to be used when creating a control tunnel.
Authentication Algorithm Select the authentication algorithm to be used when creating a control tunnel.
Item Description
Lifetime After Establishing SA Specify the validity period of a key generated when creating a communication tun-
nel.
Security Protocol Select the security protocol.
ESP Encryption Algorithm When "ESP" is selected for "Security Protocol", specify the ESP encryption algo-
rithm.
ESP Authentication Algorithm When "ESP" is selected for "Security Protocol", specify the ESP authentication al-
gorithm.
AH Authentication Algorithm When "AH" is selected for "Security Protocol", specify the AH authentication algo-
rithm.