Lantronix 900-588 Network Card User Manual


 
5: Configuration Using Web Manager
Connect Protocol
Connection Protocol Description
Protocol
Select UDP from the drop-down menu.
Datagram Mode
Datagram Mode
Settings
Description
Datagram Type
Configures the remote IP or network broadcast address and the
remote port. Enter 01 for directed or broadcast UDP. The default
setting is 00.
Accept Incoming
Select Yes to accept incoming UDP datagrams.
Endpoint Configuration
Endpoint Configuration
Settings
Description
Local Port
Enter the local port number.
Remote Port
Enter the port number of the remote device.
Remote Host
Enter the IP address of the remote device.
Use Broadcast
Select to broadcast the UDP datagram. The default is not to
broadcast.
Note: Datagrams are sent as subnet-directed broadcasts.
Device Address Table
The table is enabled when Datagram Type is set to FD. Enter values
between 1 and 255 to identify units on the local network of device
servers.
Note: Lantronix Tech Support supports Datagram type 01. Datagram
Type FD is for OEM use.
3. When you are finished, click the OK button.
4. On the main menu, click Apply Settings.
Apply Settings
1. To save and apply the configuration changes to the device server, click the Apply
Settings button.
Note: Clicking OK on each page does not change the configuration on the device.
Clicking the OK button tells the MatchPort what changes to use; the Apply Settings
makes the changes permanent and reboots the Micro125.
Micro125 User Guide 33