8: Setup Mode: Channel Configuration
Connect Mode
Connect Mode defines how the unit makes a connection, and how it reacts to incoming
connections over the network.
ConnectMode (C0) ? _
Enter Connect Mode options in hexadecimal notation.
Note: All bit positions in the table that are blank represent “don’t care” bits, for that particular
option, which can be set to either a 0 or 1 value.
Table 8-6. Connect Mode Options
Connect Mode Option 7 6 5 4 3 2 1 0
a) Incoming Connection
Never accept incoming
0
0
0
Accept with active Modem Control In
0
1
0
Always Accept
1
1
0
b) Response
Nothing (quiet)
0
Character response (C=connect,
D=disconnect, N=unreachable)
1
c) Active Startup
No active startup
0
0
0
0
With any character
0
0
0
1
With active Modem Control In
0
0
1
0
With a specific start character
0
0
1
1
Manual connection
0
1
0
0
Autostart
0
1
0
1
Hostlist
0
0
1
0
d) Datagram Type
Directed UDP
1
1
0
0
e) Modem Mode
No Echo
0
0
1
1
Data Echo & Modem Response
(Numeric)
0 1 1 1 1
Data Echo & Modem Response
(Verbose)
0 1 1 1 0
Modem Response Only (Numeric)
0
0
1
1
1
1
Micro125 User Guide 44