Lantronix 900-653-R Server User Manual


 
5: Configuration Using Web Manager
xDirect User Guide 30
Pack Control
Flush Input Buffer (Serial to Network)
Flush Output Buffer (Network to Serial)
Baud Rate The unit and attached serial device, such as a modem, must agree on a
speed or baud rate to use for the serial connection. Valid baud rates are
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, and
230400 baud. Additionally, 921600 and 460800 baud rates are available
when CPU is set to High. The default setting is 9600.
Data Bits Indicates the number of bits in a transmitted data package. The default
setting is 8.
Parity Checks for the parity bit. The default setting is None.
Stop Bits The stop bit follows the data and parity bits in serial communication. It
indicates the end of transmission. The default setting is 1.
Enable Packing Select to enable packing on the xDirect.
Two firmware-selectable packing algorithms define how and when packets are
sent to the network.
The standard algorithm is optimized for applications in which the unit is used in
a local environment, allowing for very small delays for single characters, while
keeping the packet count low.
The alternate packing algorithm minimizes the packet count on the network
and is especially useful in applications in a routed Wide Area Network (WAN).
Adjusting parameters in this mode can economize the network data stream.
Disabled by default.
Idle Gap Time Select the maximum time for inactivity. The default time is 12 milliseconds.
Match 2 Byte Sequence Use to indicate the end of a series of data to be sent as one group. The
sequence must occur sequentially to indicate end of the data collection to the
xDirect. The default setting is No.
Match Bytes Use to indicate the end of a series of data to be sent as one group. Set this
value to 00 if specific functions are not needed.
Send Frame Immediate After the detection of the byte sequence, indicates whether to send the data
frame or the entire buffer. Select Yes to send only the data frame. The default
setting is No.
Send Trailing Bytes Select the number of bytes to send after the end-of-sequence characters. The
default setting is None.
With Active Connect Select Yes to clear the input buffer with a connection that is initiated from
the device to the network. The default setting is No.
With Passive Connect Select Yes to clear the input buffer with a connection initiated from the
network to the device. The default setting is No.
At Time of Disconnect Select Yes to clear the input buffer when the network connection to or
from the device is disconnected. The default setting is No.
With Active Connect Select Yes to clear the output buffer with a connection that is initiated from
the device to the network. The default setting is No.
With Passive Connect Select Yes to clear the output buffer with a connection initiated from the
network to the device. The default setting is No.