Lantronix 900-653-R Server User Manual


 
10: Firmware Upgrades
xDirect User Guide 62
Figure 10-2 TFTP Window
After the firmware has been loaded and stored, which takes approximately 8 seconds to complete,
the unit performs a power reset.
Using TFTP: Command Line Interface
To download new firmware from a computer:
1. Enter the following from a TFTP command line interface:
tftp –i <ip address> put <local filename> <destination file name>
The following examples demonstrate the TFTP command sequence to download the .rom file and
the .cob file:
tftp –i 192.168.1.111 put xdirect_6900.rom U5
tftp –i 192.168.1.111 put xdirect_webm_2000.cob WEB1
Recovering the Firmware Using the Serial Port and DeviceInstaller
If for some reason the firmware is damaged, you can recover the firmware file by using
DeviceInstaller to download the *.ROM file over the serial port.
To recover firmware:
1. Start DeviceInstaller. If your PC has more than one network adapter, a message displays.
Select an adapter and click OK.
2. From the Tools menu, select Advanced/Recover Firmware. The Serial Port Firmware
Upgrade window displays.
3. For Port on PC, enter the COM port on the PC that is connected to the serial port of the
Lantronix unit.
4. For Device Model, be sure the appropriate device (e.g., xDirect) displays.
5. For Firmware File, click the Browse button and go to the location where the firmware file
resides.
Note: Make sure the xDirect on which you are recovering firmware is connected to this
selected port on your PC.