Lantronix 900-653-R Server User Manual


 
8: Setup Mode: Channel Configuration
xDirect User Guide 51
Disable or enable the xDirect's ability to show the IP address after RING in Modem Mode. The
default is Y (Yes), to show the IP address.
Auto Increment Source Port
Auto increment source port (N) ? _
Y (Yes) auto increment the source port. The xDirect increments the port number used with each
new connection.
Remote IP Address
This is the destination IP address used with an outgoing connection.
Remote IP Address : (000) (000) (000) (000)_
Note: This option does not display when Hostlist is enabled from the ConnectMode
prompt (see Connect Mode for more information).
Remote Port
You must set the remote TCP port number for the unit to make outgoing connections. This
parameter defines the port number on the target host to which a connection is attempted.
Remote Port (0) ? _
To connect an ASCII terminal to a host using the unit for login purposes, use the remote port
number 23 (Internet standard port number for Telnet services).
Note: This option does not display when Hostlist is enabled from the ConnectMode
prompt (see Connect Mode for more information).
Disconnect Mode (DisConnMode)
This setting determines the conditions under which the unit will cause a network connection to
terminate. The default setting is 00.
DisConnMode (00) ? _
Notes:
In DisConnMode (Disconnect Mode), when Modem Control In is not asserted, this
condition either drops the connection or is ignored.
All bit positions in the table that are blank represent “don’t care” bits for that particular
option, which can be set to either a 0 or 1 value.