Lantronix 900-653-R Server User Manual


 
8: Setup Mode: Channel Configuration
xDirect User Guide 47
Host List Option (Hostlist)
Figure 8-8 Host List Option (Hostlist)
Baudrate (9600) ?
I/F Mode (4C) ?
Flow (00) ?
Port No (10001) ?
ConnectMode (25) ?
Send ‘+++’ in Modem Mode (Y) ?
Show IP addr after ‘RING’ (Y) ?
Auto increment source port (N) ?
Hostlist :
01. IP : 172.019.000.000 Port : 00023
02. IP : 019.019.002.000 Port : 03001
03. IP : 172.019.003.000 Port : 00000
Change Hostlist ? (N) ? Y
01. IP address : (172) .(019) .(000) .(000) 001 Port : (23) ?
02. IP address : (019) 172.(019) .(002) .(000) 002 Port : (30) ?
03. IP address : (172) .(019) .(003) 000.(000) 003 Port : (0) ?
04. IP address : (000) .(000) .(000) .(000)
Hostlist :
01. IP : 172.019.001.000 Port : 00023
02. IP : 172.019.002.000 Port : 03001
03. IP : 172.019.003.000 Port : 10001
Change Hostlist ? (N) ?
Hostlist Retrycounter (3)
Hostlist Retrytimeout (250) ?
DisConnMode (01) ?
FlushMode (00) ?
DisconnTime (00:00) ?:
C0.0.0.0/0 Enters Monitor Mode.
Cwww.lantronix.com/80 Tries to connect to the Lantronix web server if the <hostname:domain>
(www.lantronix.com) is configured in the DNS server database.
Autostart (Automatic
Connection)
If you enable Autostart, the unit automatically connects to the remote IP
address and remote port specified when the firmware starts.
Hostlist If you enable this option, the device server scrolls through the hostlist until it
connects to a device listed in the hostlist table. Once it connects, the unit
stops trying to connect to any others. If this connection fails, the unit
continues to scroll through the table until it is able to connect to another IP in
the hostlist.
Hostlist supports a minimum of 1 and a maximum of 12 entries. Each entry
contains the IP address and the port number.
The hostlist is disabled for Manual and Modem Modes. The unit does not
accept a data connection from a remote device when the hostlist option is
enabled.
Command String Result if remote IP is 129.1.2.3 and remote port is 1234