Repeating defects appear on prints
Action Yes No
Step 1
a Replace the imaging unit if the distance between the defects is equal
to any of the following:
• 47.8 mm (1.88 in.)
• 96.8 mm (3.81 in.)
• 28.5 mm (1.12 in.)
b Resend the print job.
Do repeating defects still appear on prints?
Go to step 2. The problem is solved.
Step 2
a Replace the fuser if the distance between the defects is equal to either
of the following:
• 94.25 mm (3.71 in.)
• 95.2 mm (3.75 in.)
b Resend the print job.
Do repeating defects still appear on prints?
Contact
customer
support.
The problem is solved.
Troubleshooting 316