Mitsubishi Electronics 700 Series Power Supply User Manual


 
123
Sequence Instructions
3
SEQUENCE PROGRAMMING
3.25.5 Output Instructions : Bit device, timer, counter ... OUT
Functions
(1) Outputs the operation result up to OUT instruction to the specified device.
Usable Devices
Digit
Designation
Error
Flag
Bit devices
Word (16-bit)
devices
Constants Level
XYMTCDKH N
(M9010,
M9011)
Bit device
{{
Timer
Device
{
Setting
{{
Counter
Device
{
Setting
{{
OUT (Y, M)
Operation Result
OUT Instruction
Coil
Contacts
N/O contact N/C contact
OFF OFF Not energize Energize
ON ON Energize Not energize
REMARKS
Three steps are used for the OUT instruction only when the following device is used.
Special relay (M)
T0
T0
C0
C1
OUT
Y15
Device number
K50
Device number (T0 to 7)
D10
K50
Device number (C0 to 7)
OUT
OUT
Device number (T0 to 7)
Device number (C0 to 7)
(Y, M)
(T)
(C)
D10
Setting
Any of data register
contents 1 to 32767
is valid
Setting
Any of 1 to 32767 is
valid
Setting
Any of 1 to 32767 is
valid
Setting
Any of data register
contents 1 to 32767
is valid