51
CC-Link I/O Specifications
2
CC-Link COMMUNICATION
("n" indicates a value determined according to the station number setting.)
*1 Signal names are initial values. Using Pr. 180 to Pr. 186, Pr. 188, and Pr .189, you can
change input signal functions.
Signals of the RYn0, RYn1, and RYn9 can not be changed. Even when changed using Pr.
178, Pr. 179, and Pr. 187, the settings are invalid.
Refer to the inverter manual (applied) for details of Pr. 178 to Pr.189.
*2 Signal names are initial values. Using Pr. 190 to Pr .196, you can change output signal
functions.
Refer to the inverter manual (applied) for details of Pr. 190 to Pr.196.
(2) Remote resister
("n" indicates a value determined according to the station number setting.)
(3) Data I/O image
RY(n+1)B
to
RY(n+1)F
Reserved
RX(n+1)B
Remote station Ready
RX(n+1)C
to
RX(n+1)F
Reserved
PLC function
device No.
Address Description
PLC function
device No.
Address Description
D9062 RWwn
Registers designed to
read data received
from the master
station
D9078 RWrn Registers designed to
write data to be sent
to the master station.
D9063 RWwn+1 D9079 RWrn+1
D9064 RWwn+2 D9080 RWrn+2
D9065 RWwn+3 D9081 RWrn+3
REMARKS
Use the remote registers freely since they are all user areas.
PLC
function
device
No.
Remote
output
device
No.
Signal
PLC
function
device
No.
Remote
input
device
No.
Signal
Devices in CC-Link (station No. 1)
RY00 to 0F
RX00 to 0F
RWw0
RWw1
RWw2
RWw3
RWr0
RWr1
RWr2
RWr3
Devices in built-in sequence
X30 to 3F
Y30 to 3F
D9062
D9063
D9064
D9065
D9078
D9079
D9080
D9081
Automatically refreshed at every END.
FR-A700 series
Master station