Moxa Technologies C360 Computer Hardware User Manual


 
~6~
hapter 2
Hardware Installation
2.1 Installation of C360
Step 1: Choose a PC that has DOS system inside.
NOTE: No matter what OS used, user has to configure the C360
Control Board via IO-IRQ.EXE under DOS.
Step 2: Power off the PC.
Step 3: Install the C360 Control Board(s) into a 16-bit slot(s).
NOTE: If installing more than one C360 Control Boards, insert ONE
AT A TIME and configure it using the IO-IRQ.EXE
program before inserting the next board. Each C360
Control Board must have unique base I/O address and IRQ.
The C360 Control Board has the following default (factory) settings:
BASE I/O address : 300H
IRQ : 2/9
Interface : BNC (10BASE-2)
Check if any existing board has the same I/O address or IRQ. If so,
user must try to avoid the conflict by doing either one of the
following:
a. Unplug the conflicting board temporarily if possible. Then
restore the board after changing the I/O address or IRQ of C360.
b. Change or disable the existing board's I/O address or IRQ in
advance.
C