Moxa Technologies VPort 2140 Network Card User Manual


 
%s second
%t tenth second
Practical Examples
Command line Description
MAB=1C; When any motion is detected on channel 1 or 2, “Normal
Close” of relay output 1 will short with “Common”.
1H*2\=(5)1O; When DI1 high companied with DI2 transient from high
to low, “Normal Open” of relay output 1 will short with
COMMON in 5 seconds.
B\+C\+D\=W{192.168.0.1:6000}{no
signal!};
If there is no signal on channel 2 or 3 or 4, a message “no
signal!” will be sent to port 6000 of 192.168.0.1 once.
1H=VAP14; When sensor input 1 is high, drive the camera mapped to
video 1 to go to preset location 15.
MCD=UF+SABCD+N{video%c%a@
%y%M%d%h%m%s};
If any motion is detected on channel 3 or 4, upload
snapshots taken on channel 1, 2, 3 and 4. If an event
triggered at 19:05:30 2002/10/15, the snapshot files will
be named as,
video1pre@20021015190530.jpg,
video2pre@20021015190530.jpg
video3pre@20021015190530.jpg,
video4pre@20021015190530.jpg
video1trg@20021015190530.jpg,
video2trg@20021015190530.jpg
video3trg@20021015190530.jpg,
video4trg@20021015190530.jpg
video1pos@20021015190531.jpg,
video2pos@20021015190531.jpg
video3pos@20021015190531.jpg,
video4pos@20021015190531.jpg
The script file is limited to a maximum of 500 characters. The actual performance will depend
on the complexity of the command script.
VPort 2140 User’s Manual