Multi Tech Equipment ISIHI-2S Modem User Manual


 
130 MultiModemISI Hybrid Series, ISIHI-2S
Appendix
Appendix D: ISIHI-2S Testing Utilities
This disk contains two files to be used in conjunction with MutiModemISI boards. These
files are described in two sections:
Operation with factory default settings (file name: ISI608.BIN)
Operation with other than the factory default settings (file name: 608TERM.EXE)
Note: This program is a DOS utility.
1. Operation with factory default settings:
The 608TERM.EXE program is a utility program that emulates a terminal to test the
connection from PC keyboard to ISI board to Modem to ISI board to PC display. Before
executing 608TERM, the program must be executed to initialize the ISI board (when the
ISI board’s factory settings are unchanged). The following displays:
ISI608 Terminal Utility Version 1.00
Loading Firmware to ISI608 located at address 200h
Loading default file: ISI608.BIN
ISI608 loading firmware . . .
ISI608 verifying firmware . . . Verify OK.
ISI608 firmware loaded successsfully.
ISI firmware loaded successfully . . .
Enter 1 to 8 for eight ports ISI.
Enter port number?
Note: This program must be run anytime the PC is powered down or rebooted.
The first step in this utility is to identify the port to be tested. In order for the test to
function, the selected port must be connected to an activated modem. The valid entries
for the MutiModemISI are 1 through 8. Once a port is selected, the following displays:
Enter 8 == 1200 baud
Enter 11 == 2400 baud
Enter 15 == 9600 baud
Enter 16 == 19200 baud
Enter 17 == 38400 baud
Enter 18 == 57600 baud
Enter 19 == 115200 baud
Enter the baud rate you wish to run?