National Instruments AT E Series Network Card User Manual


 
Appendix A Specifications for AT-MIO-16E-1, AT-MIO-16E-2, and AT-MIO-64E-3
AT E Series User Manual A-2 ni.com
Input signal ranges
Input coupling.........................................DC
Max working voltage
(signal + common mode)........................Each input should remain
within ±11 V of ground
Overvoltage protection ...........................±25 V powered on,
± 15 V powered off
Inputs protected
100-pin devices................................ACH<0..63>, AISENSE,
AISENSE2
68-pin devices..................................ACH<0..15>, AISENSE
FIFO buffer size
AT-MIO-16E-1................................8,192 samples
AT-MIO-16E-2,
AT-MIO-64E-3................................2,048 samples
Data transfers..........................................DMA, interrupts,
programmed I/O
DMA modes ...........................................Single transfer, demand transfer
Configuration memory size ....................512 words
Range
(Software
Selectable)
Input Range
Bipolar Unipolar
20 V ±10 V
10 V ±5 V 0to10V
5V ±2.5 V 0to5V
2V ±1 V 0to2V
1V ±500 mV 0to1V
500 mV ±250 mV 0to500mV
200 mV ±100 mV 0to200mV
100 mV ±50 mV 0to100mV