National Instruments AT E Series Network Card User Manual


 
Appendix A Specifications for AT-MIO-16E-1, AT-MIO-16E-2, and AT-MIO-64E-3
AT E Series User Manual A-10 ni.com
RTSI
Trigger lines............................................7
Calibration
Recommended warm-up time.................15 min
Calibration interval.................................1 year
External calibration reference.................>6 and <10 V
Onboard calibration reference
Level................................................5.000 V (±3.5 mV) (over full
operating temperature, actual
value stored in EEPROM)
Temperature coefficient...................±5 ppm/°Cmax
Long-term stability..........................±15 ppm/
Bus Interface
Type.................................................Slave
Power Requirement
+5 VDC (±5%) .......................................1.0 A
Power available at I/O connector............+4.65 VDC to
+5.25VDCat1A
Physical
Dimensions
(not including connectors)......................33.8 by 9.9 cm
(13.3by3.9in.)
I/O connector
AT-MIO-16E-1,
AT-MIO-16E-2................................68-pin male SCSI-II type
AT-MIO-64E-3................................100-pin female 0.050 D-type
1,000 h