NETGEAR M4100-D10-POE Switch User Manual


 
Utility Commands
543
ProSafe M4100 and M7100 Managed Switches
show logging email config
This command displays information about the email alert configuration.
Format show logging email config
Mode
Email Alert Logging
Email Alert From
Address
Email Alert Urgent
Severity Level
Email Alert Non Urgent
Severity Level
Email Alert Trap Severity
Level
Email Alert Notification
Period
Email Alert To Address
Table
Email Alert Subject Table
For Msg Type urgent,
subject is
For Msg Type
non-urgent, subject is
show logging email statistics
This command displays email alerting statistics.
Format show logging email statistics
Mode
Privileged EXEC
Term Definition
The administrative status of the feature: enabled or disabled
The email address of the sender (the switch).
The lowest severity level that is considered urgent. Messages of this type are
sent immediately
.
The lowest severity level that is considered non-urgent. Messages of this type,
up to the urgent level, are collected and sent in a batch email. Log messages
that are less severe are not sent in an email message at all.
The lowest severity level at which traps are logged.
The amount of time to wait between non-urgent messages.
The configured email recipients.
The subject lines included in urgent (Type 1) and non-urgent (Type 2)
messages.
The configured email subject for sending urgent messages.
The configured email subject for sending non-urgent messages.
Privileged EXEC
Term Definition
Email Alert Operation
Status
The operational status of the email alerting feature.
No of Email Failures
The number of email messages that have attempted to be sent but were
unsuccessful.