Nu Technology cPCI-6760DK/P5 Computer Hardware User Manual


 
8 Introduction
Environment
Operating temperature: 0 to 60°C
(Note)
Storage temperature: -20 to 80°C
Humidity: 5% to 95% non-condensed
Shock: 15G peak-to-peak, 11ms duration, non-operation
Vibration:
ü Non-operation: 1.88Grms, 5-500Hz, each axis
ü Operation: 0.5Grms, 5-500Hz, each axis, with 2.5” HDD
Note: 1. System forced cooling airflow with minimum 5 CFM is required
for cPCI-6760DK/P5
2. Due to environmental limitation differences from one
component to another; please refer to the component
specification when users wishes to mount a HDD on to the
cPCI-6760DK. The operating temperature was tested with the
HDD cabling outside the testing chamber, and with a Low
Voltage Pentium-III 500MHz CPU.
3. The vibration limitation of operation is caused by the 2.5” ATA
HDD. If users wish to deploy the cPCI-6760DK/P5 into a high
vibrating environment, we suggest users to adopt Flash2000
Flash Disk (FFD series) or CompactFlash Card to replace the
2.5” ATA HDD.
Safety Certificate and Test
CE, FCC Class B
HALT (temperature and vibration stress)
Power Consumption
Configurations +5V +3.3V +12V -12V
Low Power Pentium III 500MHz,
256MB with cPCI-R6760D
2.75A
3.5A 157mA
0mA
Note: The above values are the measured power consumption for SBC
with CPU and RAM only; the CPU is running at 100% loading with
HCT, Kpower and burn-in test programs under Windows 2000
Professional. The powers for all the other peripheral devices
such as add-on cards, HDD, or CD-ROM are not included.