Oki 2400 Printer User Manual


 
4-44 Service Manual
24xx
Sensor, Pull Tractor Removal
1. Remove the top cover. Go to Covers, Top Removal on
page 4-8.
2. Remove the small screw securing the pull tractor sensor to the
inside of the left frame. Go to Sensors Removals on
page 4-43.
3. Disconnect the pull tractor sensor from the logic board.
Sensor, Head Gap Removal
1. Remove the top cover. Go to Covers, Top Removal on
page 4-8.
2. Remove the screw from the forms thickness lever and remove
the lever.
3. Remove the screw from the head gap sensor and remove the
sensor.
4. Disconnect the head gap sensor cable from the logic board. Go
to Sensors Removals on page 4-43.
Sensor, Top-Of-Form Removal
1. Remove the top cover. Go to Covers, Top Removal on
page 4-8.
2. Remove the print unit. Go to Print Unit Removal on
page 4-28.
3. Turn the print unit upside down.
4. Unsnap the Top-Of-Form sensor from the platen. Go to
Sensors Removals on page 4-43.