Paradyne 7610 Computer Hardware User Manual


 
Configuration Option Tables
A-19
7610-A2-GB20-10
November 1997
Table A-7. Telnet Session Options (2 of 2)
Session Access Level
Possible Settings: Level 1, Level 2, Level 3
Default Setting: Level 1
The Telnet session access level is interrelated with the access level of the Login ID.
Level 1 – This is the highest access level. Access level is determined by the Login ID. If
Login Required is disabled, the session access is level 1.
Level 2 – This access level overrides a Login ID with an access level 1. If a Login ID
has an access level of 3, the effective access level is 3.
Level 3 – This access level provides the effective access level and overrides the
access level of a Login ID.
NOTE: Refer to the
ATI Access
section of Chapter 4 for access level details.
Inactivity Timeout
Possible Settings: Enable, Disable
Default Setting: Disable
Provides automatic logoff of a Telnet session.
Enable – The Telnet session terminates automatically after the Disconnect Time set in
the next option.
Disable – A Telnet session will not be closed due to inactivity.
Disconnect Time (minutes)
Possible Settings: range 1 – 60
Default Setting: 5
Number of minutes of inactivity before a Telnet session terminates automatically.
Timeout is based on no keyboard activity.
H Disconnect Time (minutes) option appears when Inactivity Timeout is enabled.
1 to 60 – The Telnet session is closed after the selected number of minutes.