Paradyne 7610 Computer Hardware User Manual


 
MIB Descriptions
C-5
7610-A2-GB20-10
November 1997
Table C-2. Interfaces Group Objects (2 of 4)
Object Setting/ContentsDescription
ifType
(ifEntry 3)
Identifies the interface
type based on the
physical/link
protocol(s), right below
the network layer.
Supported values:
H other(1) – Used for the DDS network.
H ppp(23) – Used for the In-band
Management Channel and for the
Management port, when configured for
PPP.
H slip(28) – Used for Management port,
when configured for SLIP.
H rs232(33) – Used for the Terminal port
and the Management port, when not
configured as Net Link.
H v35(45) – Used for the User Data port.
ifMtu
(ifEntry 4)
Identifies the largest
datagram that can be
sent or received on an
interface (Management
port or IMC).
Number of octets.
ifSpeed
(ifEntry 5)
Provides the current
bandwidth for the
interface in bits per
second.
H Management port – Configured data rate
for the port.
H Terminal port – Configured data rate for
the port.
H DDS – Line rate of 56,000 or 64,000 bps,
reflecting the line rate detected by the unit.
H User data (DTE) port – Current data rate of
the port (DDS operating rate minus IMC
rate).
H In-band Management Channel –
Configured data rate for the In-band
Management Channel.
ifAdminStatus
(ifEntry 7)
Provides interface
status. Supported as
read-only.
H up(1) – The interface is enabled.
H down(2) – The interface is disabled.