Paradyne 8540 Network Card User Manual


 
SNMP Traps
B-4
8000-A2-GB20-50April 2000
Table B-1. DSL Card Traps (2 of 4)
Event MIBTrap #CommentSeverity
Device failure major Access Nodes operating
software has detected an
internal device failure.
15 hot_sys.mib
(Hotwire
system)
DHCP filter
security failure
minor Cannot add new route to
route table because
maximum number of stored
rules reached.
11 hot_dhcp.mib
(Hotwire DHCP
Relay Agent)
xDSL link down
analysis trap
major Sending protocol entity
recognizes that the xDSL
communication link is down
and lists reason:
H Normal Normal
power-up training
sequence
H Rate adaption Retrain
due to rate adaption
speed change
H Low margin Retrain
due to margin falling
below threshold
H Low RSL Retrain due
to receive signal level too
low
H High SNL Retrain due
to signal-to-noise level
too high
H High CRCs Retrain due
to excessive cyclic
redundancy check errors
H High RS Retrain due to
excessive Reed-Solomon
buffer overflows
H Change power Retrain
due to startup message
containing a different
transmitter power level
than the current
operating level
H Default power Retrain
and revert to default -6bl
transmitter level after a
failure to train at the last
configured level
21 hot_xdsl.mib
(Hotwire XDSL
Interface)
xDSL link up or
down
Transitions
threshold
exceeded
minor Number of link down events
above threshold. This rate is
limited to once every
15 minutes.
1 hot_xdsl.mib
(Hotwire XDSL