Paradyne 8540 Network Card User Manual


 
Monitoring the Hotwire DSL System
4-9
8000-A2-GB20-50
April 2000
Table 4-2. Physical Layer Options (5 of 5)
DSL Error Stats B-B-F
Displays the error performance (margin) rates for each of the DSL ports after selecting a
specific DSL port number. Margin is a measure of performance.
Enter port number to see the fields for current 15-minute period (real-time count of
events during the past 0 to 15 minutes), previous 15-minute period (data updated every
15 minutes), previous 1-hour period (data updated every hour), and current day, starting
at 12:01 a.m. (data updated every hour). A margin of 0 db equals an expected bit error
rate of 10
-7
. (The higher the margins, the fewer the errors.)
You may press Ctrl-r at any time to reset counters.
Port # Enter number of the port (14) you wish to monitor.
dn margin Measure of the noise margin on the specified port in the downstream
direction.
up margin Measure of the noise margin on the specified port in the upstream
direction.
dn err rate This statistic is not available for this release and an NA appears for each
time period.
up err rate Block error rate in upstream direction. Error rate = bad blocks/good blocks
and is expressed as A x 10
-B
.
dn err secs (dn err mins for Model 8540) Count of the number of down error seconds
with at least one block error.
up err secs (up err mins for Model 8540) Count of the number of up error seconds
with at least one block error.
dn svr err sec This statistic is not available for this release and an NA appears for
each time period.
up svr err sec Count of the number of seconds with at least 800 block errors.
DSL Xmit Status (DSL Transmit Stats) B-B-G
Displays the transmit and receive statistics for each of the DSL ports after selecting a
specific DSL port number.
Enter port number to see the fields for current 15-minute period (real-time count of
events during the past 0 to 15 minutes), previous 15-minute period (data updated every
15 minutes), previous 1-hour period (data updated every hour), and current day, starting
at 12:01 a.m. (data updated every hour).
You may press Ctrl-r at any time to reset counters.
Port # Enter number of the port (14) you wish to monitor.
dn xmit pwr Measure of the power level of the downstream signal sent to the RTU
(in db).
up xmit pwr Measure of the power level of the upstream signal sent to the RTU
(in db).
dn rx gain Measure of how much amplification was applied to the signal received at
the RTU.
up rx gain Measure of how much amplification was applied to the signal received at
the RADSL port.
dn att est Measure of the downstream transmission loss on the DSL line.