Patton electronic 2701RC Network Card User Manual


 
21
22
The Main Menu options are briefly described below.
System Configuration options allow you to change various
aspects of the Model 2701RC operation, e.g., framing, line
coding, and aggregate bandwidth.
System Diagnostics/Statistics options allow you to monitor
the network performance, initiate V.54 loops, local loops, and
send test patterns. Network performance parameters are
updated once a second, giving you the ability to quickly deter-
mine if there is a problem.
Unit Options allow you to customize the Model 2701RC for
your location. You can change the default header names to
give each unit a unique name and password. Also, you can
reset the unit to its default settings without the manual. It also
has a Service Information screen in case you need technical
assistance from Patton.
Save Changes Once you have configured the unit to your
satisfaction, you can save the changes permanently by exe-
cuting the Save Changes command. This will update the unit’s
configuration and save all the parameters to permanent mem-
ory.
Logoff For security, log off the control menu by executing the
Logoff command. This will blank the screen until an [Enter]
key is pressed.
3.3.4 System Configuration
The System Configuration menu looks like this:
The System Configuration options are described below:
Line Format: G.703
(default)
Options: G.703, G.704
G.703: G.703 is unframed, 2.048Mb/s. In this case, the DTE rate
is equal to the line rate at the network interface (NI). CAS MF
and CRC-4 are disabled.
G.704: G.704 reserves TS0 for signaling and frame alignment.
Maximum data rate depends on whether CAS MF is enabled
or not.
a
b
c
d
e
a