Patton electronic 2701RC Network Card User Manual


 
43
44
To perform a V.52 test, follow these steps:
1. Activate the local loopback or remote loopback diagnostic.
2. Activate the test pattern. This may be done in one of two
ways:
a. Enter Test Pattern from the System
Diagnostics/Statistics menu and toggle the <Spacebar>
until the desired test pattern appears.
One of two result codes will appear to the right of the
Test Pattern listing:
OK Indicates that the received test pattern is error-free.
BE Indicates that there are errors in the test pattern (to
deliberately insert errors in the pattern, toggle
Error Insertion to ON).
b. Toggle the front panel switch to either PAT or PAT/E (Test
Pattern with Error Injection).
APPENDIX A
PATTON MODEL 2701RC
SPECIFICATIONS
Network Data Rate: 2.048 Mbps
Network Connector: RJ-48C or dual BNC
Nominal Impedance: 120 ohm (75 ohm available when using
Patton Model 1001RCM11575 rear
card)
DTE Interface: V.35 (DCE Orientation) X.21 (DCE or
DTE orientation), RS-530, RS-232,
10Base-T, Ethernet
Line Coding: Selectable AMI or HDB3
Line Framing: G.703 (Unframed) or G.704/G.732
(Framed)
CAS Multiframing: Selectable On or Off
CRC-4 Multiframing: Selectable On or Off
Clocking: Internal, External, or Receive Recover
DTE Data Rates: 64, 128, 192, 256, 320,384, 448, 512,
576, 640, 704, 768, 832, 896, 960,
1024, 1088, 1152, 1216, 1280, 1344,
1408, 1472, 1536, 1600, 1664, 1728,
1792, 1856, 1920, 1984, 2048 kbps
Time Slot Rate: 64 kbps
DS0 Start Position: Arbitrary
DS0 Mapping Position: Contiguous or Arbitrary
Diagnostics: V.54 Loopback; V.52 Patterns: 511,
2047, and QRSS
Indicators: Power, Transmit Data, Receive Data,
Alarm, Loss of Sync, Test Mode, Error
Configuration: Two 8-Position DIP Switches, RS-232
Control Port, or SNMP Managable
Power Supply: 100-240VAC, 50-60Hz, 0.4A
Humidity: Up to 90% non-condensing
Temperature: 0 to 70