Using a browser to complete Model 3196RC configuration 45
Model 3196RC T-DAC User Manual 3 • Configuring the T-DAC for operation
4. To enter the default gateway, use the first
Add a route line
. The Destination shall remain 0.0.0.0, and there
is no mask to enter.
5. In the Gateway box, type your default gateway IP address for the 3196RC.
6. Click the Add Route button to save your configuration.
Figure 25. IP Routing Information window
7. The route which you already see in the table appeared upon the configuration of the LAN IP address.
8. To enter the default gateway, use the first Add Route line. The Destination shall remain as 0.0.0.0. There is
no mask to enter.
9. Enter the IP address in the Gateway box. This is the default gateway.
10. Click on the
Add Route
button.
Configuring the system clocking parameters
In this section you will define clocking sources for the main reference and fallback reference on the 3196RC
TDAC. Clocking source selection will depend on the clocking role you assign to the blade: master(1), second-
ary(2), or slave(3). The master will drive the main reference clock for the chassis. Should the master fail, the
secondary will drive the main reference. Slaves will not drive any clock reference. Most often the 3196RC will
be configured as slave(3), with another blade (such as the Patton Model 6511) configured as the master(1).
As clocking sources for the 3196RC, you can choose:
Any one of the WAN ports
An internal oscillator
A WAN port from another blade module
An external 64-kHz BITS (building integrated timing supply) reference clock
Note
For the external BITS clock setting to operate, you must connect the
BITS clock system at the installation site to the EXT CLOCK connec-
tor on one of the WAN access modules installed in the rear of the
ForeFront chassis.