Distance Chart 3202 Series – Optimal Mode (TCPAM-128)
Table 5. Distance Chart Model 3202 Series – Optimal Mode
Line Rate Distance
Line
Speed
3202
2-Wire
3202
4-Wire
3202
8-Wire
26 AWG/0.4mm 24 AWG/0.5mm 22 AWG/0.65mm
N = kbps kbps kbps kft km kft km kft km
7 448 896 1792 20.0 6.1 24.0 7.3 31.0 9.4
8 512 1024 2048 19.0 5.8 23.0 7.0 30.0 9.1
10 640 1280 2560 18.0 5.5 20.5 6.2 28.0 8.5
11 704 1408 2816 17.0 5.2 19.0 5.8 26.5 8.1
16 1024 2048 4096 16.0 4.9 18.0 5.5 24.5 7.5
20 1280 2560 5120 15.0 4.6 17.0 5.2 23.0 7.0
22 1408 2816 5632 14.0 4.3 15.5 4.7 21.0 6.4
27 1728 3456 6912 13.0 4.0 14.5 4.4 20.0 6.1
34 2176 4352 8704 12.0 3.7 14.5 4.4 18.5 5.6
39 2496 4992 9987 11.0 3.4 13.0 4.0 17.0 5.2
44 2816 5362 11264 10.0 3.0 12.0 3.7 15.5 4.7
53 3392 6784 13568 9.0 2.7 10.5 3.2 13.5 4.1
73 4672 9344 18688 8.0 2.4 9.5 2.9 12.5 3.8
89 5696 11392 22784 7.0 2.1 8.5 2.6 10.5 3.2
110 7040 14080 28160 6.0 1.8 7.0 2.1 9.0 2.7
125 8000 16000 32000 5.0 1.5 6.0 1.8 7.5 2.3
152 9728 19456 38912 4.0 1.2 4.5 1.4 6.0 1.8
164 10496 20992 41984 3.0 0.9 3.5 1.1 4.5 1.4
198 12792 25584 51168 2.0 0.6 2.5 0.8 3.0 0.9