Patton electronic 3202 Modem User Manual


 
Installing the Model 3202 31
Model 3202 User Manual 3 • Hardware installation
Grounding the Model 3202 and connecting power
In connecting to the power source, it is important to establish a good grounding connection first, then the
power connection. Do the following:
1. Assemble a ground wire using #10 AWG wire with green-colored insulation and two ring terminals. Make
the wire long enough to reach one of the following earth ground sources:
The building ground rod (generally located at the site’s main service entrance)
A sprinkler system pipe
A cold-water pipe
Building structural steel
Figure 6. Grounding stud
2. Install the grounding wire between the grounding stud (see figure 6) and the grounding source.
3. Connect the power adapter to the DC 9V port on the Model 3202, and then connect to the power source.
Mains Voltage: Do not open the case the when the power cord is attached.
Line voltages are present within the power supply when the power cords are
connected. The mains outlet that is utilized to power the device shall be within
10 feet (3 meters) of the device, shall be easily accessible, and protected by a
circuit breaker.
The Model 3202 is not shipped with power cables. For AC powered units,
ensure that the power cable used meets all applicable standards for the coun-
try in which it is to be installed, and that it is connected to a wall outlet which
has earth ground.
The power supply automatically adjusts to accept an input volt-
age from 100 to 240 VAC(50/60 Hz).
MGMT
LINE
4
Grounding stud
WARNING
WARNING
IMPORTANT