Communication Failures
Errors 410 to 413 are usually caused by a hardware failure, by an
incorrect SETUP option or by the host ignoring flow control
(XON/OFF, CTS/RTS or DTR). Communication settings:
Baud rate 1200, 2400, 4800, 9600, 19200, 38400, 57600,
115200
Word length 7 or 8
Stop bits 1 or 2
Parity Odd, Even, None
Flow control None, XON/XOFF, DTR, CTS
410 Parity on the printer does not match the parity on the
host. Check the parity setting under SETUP options.
411 Framing error. The printer cannot communicate with the
host. Make sure the host is turned on, communication
cables are connected correctly, port settings are correct,
and communications are active. Check the baud rate,
word length, and stop bits to make sure they match those
at the host. Do not toggle between Microsoft® Windows®
and MS-DOS, while using the COPY command, or you
will receive a framing error. Re-transmit the data.
412 There is a problem with flow control between the printer
and the host. Make sure the printer and the host flow
control settings match (both are DTR or both are
XON/XOFF). If the error persists, call Technical
Support.
413 Online receive queue is full. Check your printer’s
XON/XOFF or DTR SETUP values to be sure there isn’t
a flow control problem.
414 The internal keyboard buffer is full or you need a new
keypad. Call Technical Support.
415 The buffer size you defined exceeds the total available
in your machine.
8-16