Status2
C- Field Number
represents the field number within each
packet. The packet header is the first
field and each subsequent field is
indicated by the field separator.
Status2
D- Parameter
represents the parameter within the field
that the error occurred. The numbering
begins after the field identifier.
Status2
E- Error Number
is the error that coincides with the error
numbers presented in Chapter 9, "Errors."
"FMT-1/BCH-2" The format or batch number is returned.
n
If more than one error occurred then only the most serious
error will be acknowledged.
{J,"","F,B,4,6,33","FMT-1","BCH-2"}
Indicates that an error occurred on a bar code (B) field within
a format (F) packet. The bar code field is the fourth (4) field in
the packet. The error occurred in the sixth (6) parameter of
the field. Error number 33 means the bar code density is
invalid.
To clear an error, press the trigger (or
E
depending on
your printer). An ENQ can also clear errors numbered less
than 500. Once the error is corrected, a job request can be
sent. The printer cannot accept another job request until the
error is resolved.
MPCLII Packet Reference Manual