Communication Failures–––––––––––––––––––––––––––––––––––––
Errors 410 to 413 are usually caused by a hardware failure, by
an incorrect SETUP option or by the host ignoring flow control
(XON/OFF, CTS/RTS or DTR).
n
The valid communication settings are shown below.
Baud rate 1200, 2400, 4800, 9600, 19200
Word length 7 or 8
Stop bits 1 or 2
Parity Odd, Even, None
Flow control None, XON/XOFF, DTR, CTS
Reset Yes or No
Error
Code
Description/Action
410 Parity on the printer does not match the parity on
the host. Check the parity setting under SETUP
options.
411 Framing error. The printer cannot communicate with
the host. Make sure the host is turned on,
communication cables are connected correctly,
communication settings are correct, and
communications are active. Check the baud rate,
word length, and stop bits to make sure they match
those at the host. Do not toggle between
MS-Windows and MS-DOS, while using the COPY
command, or you will receive a framing error. (Exit
MS-Windows before using the COPY command.)
Re-transmit the data.