54 Philips · Laserfax 5120 · 5125 · 5135
EN
Spaltenumbruch Spaltenumbruch
The device produces white lines when printing. Clean the toner drum with a soft cloth.
Clean the LED print head above the toner cartridge (see
also chapter Cleaning the LED Print Head, page 50)
Clean the scanner and the document feeder (see also chap-
ter Clean Scanner and Document Feeder, page 50).
The device produces black lines when printing. Clean the scanner and the document feeder (see also chap-
ter Clean Scanner and Document Feeder, page 50).
The toner cartridge is damaged and must be replaced. Use
only original consumable materials.
The device produces vertical lines when printing. It is possible that the scanner needs calibrating (see also
chapter Calibrating the Scanner, page 51).
The device makes a noise during printing. The toner cartridge is almost empty and must be replaced.
Use only original consumable materials.
Received faxes and copies are too light. The sender’s device is not set optimally.
If the copy is also too light the toner is almost all gone and
must be replaced. Use only original consumable materials.
Print is out of focus Clean the LED print head above the toner cartridge (see
also chapter Cleaning the LED Print Head, page 50)
Problems Printing or Copying Possible Cause(s)
lpf-5120-5125-5135-manual-uk-int-253117544-b.book Seite 54 Mittwoch, 16. Dezember 2009 10:01 10