AC CHARACTERISTICS (I
2
C pins)
All timing values are valid within the operating supply voltage and ambient temperature range and reference to V
IL
and V
IH
with an input voltage
swing of V
SS
and V
DD
.
SYMBOL
PARAMETER TEST CONDITIONS MIN MAX UNIT
f
SCL
SCL clock frequency 1000 kHz
t
BUF
Bus free time 0.5 µs
t
SU;STA
Start condition set-up time 0.25 µs
t
HD;STA
Start condition hold time 0.25 µs
t
LOW
SCL LOW time 0.45 µs
t
HIGH
SCL HIGH time 0.45 µs
t
r
SCL and SDA rise time 0.3 µs
t
f
SCL and SDA fall time 0.1 µs
t
SU;DAT
Data set-up time 100 ns
t
HD;DAT
Data hold time 0 ns
t
VD;DAT
SCL LOW to data out valid 0.4 µs
t
SU;STO
Stop condition set-up time 0.25 µs
A detailed description of the I
2
C-bus specification, with applications, is given in the brochure “
The I
2
C-bus and how to use it
”. This brochure may
be ordered using the Philips order number 9398 393 40011.
SV00756
SCL
SDA
PROTOCOL
t
SU;STA
t
LOW
t
HIGH
1/f
SCL
t
BUF
t
r
t
f
t
HD;STA
t
SU;DAT
t
HD;DAT
t
VD:DAT
t
SU;STO
BIT 0
LSB
(R/W)
ACKNOWLEDGE
(A)
STOP
CONDITION
(P)
START
CONDITION
(S)
BIT 7
MSB
(A7)
BIT 6
(A6)
Figure 4. I
2
C-bus timing diagram