Planet Technology SGSD-1022P Switch User Manual


 
User’s Manual of SGSD-1022 / SGSD-1022P
SGSW-2840 / SGSW-2840P
395
[0] 00:00:37 2001-01-01
"System coldStart notification."
level: 6, module: 5, function: 1, and event no.: 1
Console#
5.8 SMTP Alert Commands
These commands configure SMTP event handling, and forwarding of alert messages to the specified SMTP servers and email
recipients.
Command Function Mode
logging sendmail host SMTP servers to receive alert messages GC
logging sendmail level Severity threshold used to trigger alert messages GC
logging sendmail source-email Email address used for “From” field of alert messages GC
logging sendmail
destination-email
Email recipients of alert messages GC
logging sendmail Enables SMTP event handling GC
show logging sendmail Displays SMTP event handler settings NE, PE
Table 4-18 SMTP Alert Commands
logging sendmail host
This command specifies SMTP servers that will be sent alert messages. Use the no form to remove an SMTP server.
Syntax
[no] logging sendmail host ip_address
ip_address - IP address of an SMTP server that will be sent alert messages for event handling.
Default Setting
None
Command Mode
Global Configuration
Command Usage
You can specify up to three SMTP servers for event handing. However, you must enter a separate command to specify
each server.
To send email alerts, the switch first opens a connection, sends all the email alerts waiting in the queue one by one, and
finally closes the connection.
To open a connection, the switch first selects the server that successfully sent mail during the last connection, or the first